• Thank you for visiting HeavyEquipmentForums.com! Our objective is to provide industry professionals a place to gather to exchange questions, answers and ideas. We welcome you to register using the "Register" icon at the top of the page. We'd appreciate any help you can offer in spreading the word of our new site. The more members that join, the bigger resource for all to enjoy. Thank you!

ASV RC100 operating speed issue

Mastiffaruba

New Member
Joined
Mar 27, 2017
Messages
1
Location
aruba
Hi there, I have a ASV Rc100, that is stuck in hi speed, I'm running out of things to check and replace. so far I have done the following.
Replaced both Drive motors, checked hi/low speed solenoid & shaft, replaced all hydraulic filters, replaced all seals in hand controller. checked all electrical wires for any signs of open wires, check all fuses, and connection in fuse box.
I managed to get it running in low speed for about 5 minutes, went over a bump and i'm stuck in high speed again. I'm leaning towards bad electrical connection somewhere and I have been searching for a wiring diagram but no luck so far.

Any suggestions would be welcome before I set a match to it.
fiery.gif
 

Ads

Well-Known Member
Joined
Sep 12, 2015
Messages
46
Location
Australia
I'd check the wiring between the switch and the solenoid. Sounds like the rest of the components are new. :)

Adam.
 

lantraxco

Senior Member
Joined
Jan 1, 2009
Messages
7,704
Location
Elsewhen
Try disconnecting the solenoid electrically, see if that locks it in low. Other thing you can usually do (I am not familiar with the ASV) on a two speed is remove and cap the small hose that shifts the motor on each side. In other words make sure the motors are working correctly and then decide if it's a hydraulic or electrical issue
 

hackmaster

New Member
Joined
Feb 11, 2018
Messages
4
Location
ojai california
Occupation
General Contractor
Hi there, I have a ASV Rc100, that is stuck in hi speed, I'm running out of things to check and replace. so far I have done the following.
Replaced both Drive motors, checked hi/low speed solenoid & shaft, replaced all hydraulic filters, replaced all seals in hand controller. checked all electrical wires for any signs of open wires, check all fuses, and connection in fuse box.
I managed to get it running in low speed for about 5 minutes, went over a bump and i'm stuck in high speed again. I'm leaning towards bad electrical connection somewhere and I have been searching for a wiring diagram but no luck so far.

Any suggestions would be welcome before I set a match to it.
fiery.gif
 
Top