A. RECOMMENDED BOXES. C. SAFETY INSTRUCTIONS.

Suitable for mounting in flush or surface boxes with a 1. This product must be installed by a competent person in
Telephone Sockets. minimum depth of 16mm. (Except Accent and Panel Mount accordance with the current editions of the IEE Wiring
products which require a minimum box depth of 25mm). Regulations (BS7671) and Buildings Regulations. If in any
doubt, consult a qualified electrician.

Contents: B. GENERAL. 2. These products must not be installed in the same enclosure
A. Recommended Boxes as equipment rated in excess of 50V,
All MK telephone Master and Secondary outlets are either (e.g. mains rated 13A sockets or switches).
B. General
independently tested and BABT approved or tested to
C. Safety Instructions BS6312 part 2 under the OFTEL general approvals. Metal Frontplate Products:
D Panel Mounted Outlets Where it is necessary to conform with the IEE Wiring
Master Outlets:
E. Installation Instructions Regulations (BS7671), metal frontplates must be earthed.
F. Module Removal Used for the first socket outlet on a direct exchange line as
the primary Network Termination Point. Powerlink Products:
G. Disposal
(All MK Master outlets are surge protected according to Powerlink Products must be installed into the Powerlink
H. Guarantee
OFTEL requirements as defined in BS6312). Distribution system using the ELV isolation box supplied
with the Powerlink Telephone socket.
Secondary Outlets:
Panel Mount Products:
Used as extension sockets when connected on the same
line in parallel with a master socket. Panel mounted products must be installed using the rear
Please leave this leaflet with the end user isolation box supplied.
for future reference

43081PL Ed.2

D. PANEL MOUNTED OUTLETS. E. INSTALLATION INSTRUCTIONS. Note: If an existing installation uses a different wiring
Panel Mounted Outlets: 1. Where fitted remove the frontplate fixing screws from the colour code system, this should be retained on any new or
Panel mount versions are suitable for mounting in plastic or back of the product. extended installation.
metal panels of thickness from 0.9 to 2.0mm, (the panel cut 2. Ensure that the mounting box is firmly secured in position 6. Trim off any excess inner conductors protruding from the
out dimensions are shown in figure 1). The outlet is mounted and there is sufficient cable protruding for connection. IDC terminals.
after connection by passing the screws through the panel and 3. If fitting a modular product fit the appropriate mounting 7. Secure the cable to the product at the cable tie fixing point
the apertures in the outlet and securing them in the rear frame to the wall box. indicated in Figure 2 using the cable tie supplied.
isolation box supplied.
Do not over tighten the screws, to do so may damage the 8. Carefully push the wired unit back into the mounting box or
60.30 screw threads, frontplate or mounting frame. modular mounting frame ensuring that the cable does not
20.85 Ensure that any metal frame is earthed as required. have any sharp bends and is not trapped or pinched.
4. Carefully strip 50mm of the telephone cable outer sheath to With modular products locate the bottom snap-fit and then
expose the inner insulated conductors. carefully push home the top snap-fit.
5. Using a suitable IDC insertion tool, (e.g. MK list No. 9. Where relevant fit the decorative modular frontplate and if
400NAT) carefully push each lead into the appropriate applicable then locate and tighten any frontplate fixing
IDC terminal according to the wiring colour code stated in screws.
32.25 Figure 2. Do not over tighten the screws, to do so may damage the
4mm dia Pins 1 and 6 are frequently unused, 4 wire cable may be frontplate or screw threads.
Figure 1 counter sunk used in these installations.
to suit screw
Panel cut out
dimensions R2.0 max
G. DISPOSAL.
3 4 Figure 2 At the end of it useful life, product and packaging can be
safely disposed of via standard refuse facilities.
2 5 BT Wiring Scheme:
1 - GREEN / white
IDC 1 6 2 - BLUE / white
Terminals 3 - ORANGE / white H. GUARANTEE.
4 - WHITE / orange
5 - WHITE / blue The company undertakes to replace or repair at its discretion
6 - WHITE / green these products should they become defective within 10 years
solely as a result of faulty materials and/or workmanship.
Note: 1 6 Understandably if the product has not been installed or
Main wire colour is maintained in accordance with the companys instructions,
shown in capitals. 2 5 has not been used appropriately or if any attempt has been
made to rectify, dismantle or alter the product in any way the
3 4
Guarantee will be invalidated.
Cable Tie
fixing point. This Guarantee states the companys entire liability. It does
IDC Cable Tie not extend to cover consequential loss or damage or
Terminals Cable Tie. Fixing Point. installation costs arising form the defective product. This
Guarantee does not restrict or infringe the normal statutory or
Cable Tie.
other rights of the customer.
Logic Plus or Modular Accent modules, Powerlink and
Outlets. Panel Mount outlets.

Additional Secondary Extension Outlets:


F. MODULE REMOVAL
Additional secondary extension outlets may be wired in 1. Remove the decorative frontplate from the mounting frame
parallel with the existing installation via the IDC terminals, (i.e. by removing the fixing screws. For frontplates without
pin 1 to pin 1, pin 2 to pin 2 etc) see Figure 3. fixing screws, (e.g. Accent), remove the frontplate by
carefully unclipping the frontplate from the mounting frame.
Extension sockets may be connected to the master socket by This will leave the mounting frame still fixed to the wall box
a maximum of 50m of cable. The total length of wiring that with the modules clipped into it.
may be used including all branches should not exceed 100m MK Electric
In the case of Logic Plus modular system the frontplate
Novar ED&S Ltd
First Socket Outlet Extension Outlet must be removed from the wall box as the modules clip The Arnold Centre Paycocke Road Basildon
Master Secondary
directly into the frontplate Essex SS14 3EA. U.K.
1 2 3 4 5 6 1 2 3 4 5 6
2. To remove the modules from the mounting frame carefully Tel: +44 (0) 1268 563000
depress the snap-fits using a suitable flat bladed Fax: 01268 563405 (UK Sales)
screwdriver and gently remove the module from the frame. Fax: +44 (0) 1268 563360 (International)
email: technical@novar.com
With the Logic Plus modular system the snapfits will need web site: www.mkelectric.co.uk
to be depressed from the rear.
Figure 3 Technical queries should be made to:
Parallel Wiring Diagram for MK Electric, Technical Sales and Services Department
Secondary Extension Outlets
The Arnold Centre, Paycocke Road, Basildon, Essex SS14 3EA
Tel: +44 (0)1268 563720 Fax: +44 (0)1268 563064

All marks in this document identified with a R or TM symbol


adjacent to the mark are Trade Marks of Novar ED&S Limited

You might also like